2-channel precision current-voltage measurement system
OTTER I-V EXPERT
Two source-measure channels, so a transistor is characterised with a single instrument.
- 2 CH
- Independent source-measure channels
- ±80 V
- Source voltage per channel
- < 100 pA
- Noise (NPLC 1 or more)
- AI
- CLI · MCP server
Raw data from off-the-shelf devices
Measured values vary with the measurement setup and the state of the device.
Enter the conditions, press run, and the curve is drawn as it is measured
Choose one of nine measurement routines from the tabs. When it finishes, the data (csv), the measurement conditions (md) and the screen (jpg) are saved together under one name, so months later you still know which conditions produced a result.
FET transfer measurement screen — drain voltage 0.1, 1 and 5 V, gate voltage 0 to 5 V, Smart NPLC with the median filter. The screen exactly as the application saved it after the measurement.
Measure together with AI
The measurement software runs from its window, from the command line, and from an AI agent.
Let your agent run the machine.
MCP server
An AI agent checks the conditions, runs the measurement and reads the result.
CLI
The same executable runs in a terminal (--json, --dry-run). All nine measurements run with no window at all.
An AI agent measured 753 points of a CD4007 transfer characteristic from the command line and plotted the data. The screen is shown as captured.
Specifications
| Channels | 2 (independent source-measure) |
|---|---|
| Voltage | ±80 V per channel, up to 160 V between channels |
| Current | ±20 mA max, 4 ranges + AUTO |
| Noise | below 100 pA (NPLC 1 or more, after zeroing) |
| Integration time | NPLC 0.01 – 25 |
| Connectors | BNC (Ch. A, Ch. B, GND) |
| Interfaces | USB · SCPI · CLI · MCP server |
| Power | USB-PD, 45 W or higher |
| Data | csv (data), md (measurement conditions) and jpg (screen) saved together under one name |
Three BNC connectors
| Ch. A | BNC, ±80 V source-measure |
|---|---|
| Ch. B | BNC, ±80 V source-measure |
| GND | BNC |
| Power · PC | USB-C (PD 45 W) · USB-B |
Nine built-in measurement routines
Start measuring without writing a script, and run the same nine routines from the command line when you want to.
| General | I-V, FET Transfer, FET Output, I-t |
|---|---|
| Synaptic devices | EPSC / PPF, LTP / LTD |
| Memristors | Endurance, Retention, LTP / LTD |
| Pulses | Pulse Sequence (an arbitrary pulse train read from a file) |
Use it safely
This instrument outputs up to ±80 V, and with both channels in use the potential difference between them reaches 160 V.
- Do not touch the centre conductor of a BNC connector or a device electrode while the output is on.
- Turn the output off before connecting or disconnecting a device, and check that the screen shows output OFF.
- Always connect the ground electrode to the GND connector.
- Use a USB-PD charger rated at 45 W or higher.